Get two numbers at one temperature
Ask the designer for your home's winter design temperature and the heating load at that temperature, in Btu per hour. Then ask for the matched heat pump's heating capacity at the same outdoor temperature and the proposed indoor conditions. The manufacturer’s extended performance table is a useful place to look. A minimum operating temperature only tells you how far down the unit can run.
For example, suppose the calculation calls for 36,000 Btu/h and the heat pump can supply 28,000 Btu/h at that condition. That leaves 8,000 Btu/h to cover. Ask how the chosen backup heater and controls meet that gap. With a dual-fuel setup, the furnace may take over the whole load.
Try that load check with these pairs. Each comparison gives the measured winter output where available and identifies any missing test point.
Use the cold-climate label to narrow the list
ENERGY STAR evaluates cold-climate performance at 5°F. This gives you a common test point for a shortlist. If your design temperature is colder, ask to see the performance data for that colder condition and check that the indoor unit in the table matches your bid. HSPF2 describes a heating season and cannot supply this missing output figure.
Check what happens on milder days
A large heating requirement and a modest cooling requirement can pull equipment selection in different directions. Ask the designer to compare minimum cooling output with the summer load and explain how the system will handle mild, humid days. Record the backup heat source, when it is expected to run and how you can tell when it is on.
Take to the appointment
- Winter design temperature and load
- Heating output for the proposed indoor and outdoor match
- Backup sequence and minimum summer output