HVAC MatchupQuote worksheet

Homeowner guide

What is a higher efficiency rating worth?

Turn two certified cooling ratings into an energy-use comparison and a rough payback check.

Compare ratings that measure the same work

SEER2 compares seasonal cooling output with electricity used. HSPF2 covers a heat pump's heating season under defined test conditions. AFUE measures how much of a furnace's fuel becomes useful heat over a season. Start with the two SEER2 values for the actual equipment combinations if cooling electricity is your question.

Keep the assumed annual cooling delivered to the house the same for both options. A previous whole-house electric bill also includes lights, appliances and other loads. Ask how the contractor estimated the part attributable to cooling.

Work through a cooling example

Suppose each system must deliver 30 million Btu of cooling over a season. Dividing that load by 15 SEER2 and then by 1,000 gives about 2,000 kWh. At 18 SEER2 the same calculation gives about 1,667 kWh. The modeled difference is roughly 333 kWh, or one-sixth of the first unit's cooling electricity.

At an illustrative electricity rate of $0.18 per kWh, the difference comes to about $60 a year. Use your own seasonal cooling load, electricity rate and certified SEER2 values. Actual weather, system setup, duct losses and thermostat choices can change the result.

Apply the calculation to these matched systems. One pair has identical rated cooling capacity. In the other, the model with the better seasonal rating has the lower EER2.

Put the premium next to the annual difference

Ask for the extra installed cost of the higher-efficiency option with the same scope of work. Dividing that premium by the estimated annual savings gives simple payback in years when savings are positive. It leaves out financing, repairs and future price changes. For heating, have the estimator model local temperatures and any backup fuel separately.

Quieter operation, low-stage comfort or warranty coverage may also matter to you. Give those features their own lines on the comparison so you can decide what you would pay for each.

Take to the appointment

  • Certified ratings for the quoted combinations
  • Identical seasonal cooling load for both options
  • Extra installed cost and local electricity rate

References

Related guides

Open the quote worksheet