Rated equipment comparison

Carrier Infinity 27VNA1 vs. Trane TruComfort 5TCV0X

For a house with a large winter load, compare the Carrier’s higher heat output at 5°F with the Trane’s higher efficiency at that temperature.

What happens on a 50,000 Btu/h morning?

At 5°F the Carrier delivers 53,500 Btu/h of heat at a COP of 1.90. The Trane delivers 48,000 Btu/h at a COP of 2.05. If a load calculation puts the house at 50,000 Btu/h at 5°F, the Carrier has 3,500 Btu/h to spare on the rating. The Trane would need help with the last 2,000 Btu/h. In a house where both cover the load, the Trane’s higher COP at this temperature implies less electricity per unit of heat.

What backup heat is included?

The Carrier rating lists a 59TN7A100C21**22 furnace with the indoor coil. The Trane lists a 5TEMCD07BV51+TDR indoor combination. Have each installer identify the backup on the bid and its control settings. If the furnace takes over before the outdoor temperature reaches 5°F, the gas price and furnace efficiency will matter more on that morning than the Carrier’s heat pump rating.

Specifications side by side

Figures apply to the equipment combinations shown. N/A marks a field that is missing or does not apply.

SpecificationCarrier 27VNA154A*030*Trane 5TCV0X60A1
System typeSplit heat pumpSplit heat pump
Outdoor / packaged model27VNA154A*030*5TCV0X60A1
Indoor modelCSAH*6012AM*+UI5TEMCD07BV51+TDR
Furnace in this rating59TN7A100C21**22N/A
AHRI reference215588461218792279
EPA product ID37197884704986
Compressor stagingVariable-speedVariable-speed
RefrigerantR-454BR-454B
Cooling capacity49,500 Btu/h48,500 Btu/h
SEER218.519.2
EER211.511.5
HSPF29.59.4
Heat at 47°F52,500 Btu/h55,000 Btu/h
Heat at 17°F50,500 Btu/h44,000 Btu/h
Heat at 5°F53,500 Btu/h48,000 Btu/h
COP at 5°F1.92.05

Equipment sources