Size the package for both seasons
The Carrier has 46,500 Btu/h of rated cooling and the Trane has 42,000. The two-stage packages tie at 15.2 SEER2 and 7.2 HSPF2. At 5°F, though, the Trane delivers 20,000 Btu/h at a COP of 2.0 and the Carrier delivers 18,200 at 1.8. A house with a large cooling load and a house close to needing winter backup can reasonably favor different packages.
Put the cabinet connections on the bid
A package replacement has supply and return ducts at the outdoor cabinet. Have the bidder mark both openings and identify any transition needed for the selected model. On a roof, ask whether the existing curb fits and whether the price includes an adapter and lifting the unit into place. On a ground pad, compare the proposed duct transitions and access for service. These costs belong alongside the measured capacity differences.
Specifications side by side
Figures apply to the equipment combinations shown. N/A marks a field that is missing or does not apply.
| Specification | Trane 5WCZ5042A1 | Carrier 50NR-B48---30* |
|---|---|---|
| System type | Packaged heat pump | Packaged heat pump |
| Outdoor / packaged model | 5WCZ5042A1 | 50NR-B48---30* |
| AHRI reference | 216574938 | 217154367 |
| EPA product ID | 4027844 | 4010251 |
| Compressor staging | Two-stage | Two-stage |
| Refrigerant | R-454B | R-454B |
| Cooling capacity | 42,000 Btu/h | 46,500 Btu/h |
| SEER2 | 15.2 | 15.2 |
| EER2 | 11.5 | 11.5 |
| HSPF2 | 7.2 | 7.2 |
| Heat at 47°F | 39,000 Btu/h | 44,500 Btu/h |
| Heat at 17°F | 25,400 Btu/h | 25,400 Btu/h |
| Heat at 5°F | 20,000 Btu/h | 18,200 Btu/h |
| COP at 5°F | 2 | 1.8 |