How much heat comes on when the thermostat calls?
Take the Goodman rated at 40,000 Btu/h of high-fire gas input. Its published natural-gas output is 22,400 Btu/h on low and 32,000 on high. That lower setting can extend a heating cycle during milder weather. The Trane S9X1 has one firing level, so it meets a light load by cycling on and off.
Both lines include sizes from 40,000 to 120,000 Btu/h of gas input. Ask the installer for the delivered heating output of the proposed size and the house's calculated heat loss. Two furnaces with the same input can deliver different amounts of heat.
What would it cost to move to 96% AFUE?
If both furnish the same amount of seasonal heat and the quoted Trane is rated at 96% AFUE, the ratings imply about 17% less furnace gas use for the Trane than for the 80% Goodman. The burner stages describe how the heat is delivered. AFUE describes how much of the fuel's energy becomes useful heat over a season.
When replacing an existing 80% furnace, have the installer price the vent route and condensate drainage for the Trane. Compare that installed premium with the gas you use for space heating. Your summer water-heating and cooking bills can help separate that use from the rest of the gas bill.
Specifications side by side
Series figures cover several sizes. Confirm the specifications for the model on your quote.
| Specification | Goodman GR9T80 | Trane S9X1 |
|---|---|---|
| Series / model | GR9T80 | S9X1 |
| Equipment type | Gas furnaces | Gas furnaces |
| Operating stages | Two-stage | Single-stage |
| Published capacity range | 40,000–120,000 Btu/h high-fire gas input | 40,000–120,000 Btu/h gas input |
| AFUE, up to | 80% | 96% |