Rated equipment configuration
York YH936E2C11 · rating 218026826
The published rating for this configuration lists 35,000 Btu/h of cooling. Check the indoor model CTF36C5ADS1+CC against your proposal.
Equipment on the rating
- System type
- Split heat pump
- Outdoor / packaged model
- YH936E2C11
- Indoor model
- CTF36C5ADS1+CC
- Furnace in this rating
- YP9C100C16MP13
- AHRI reference
- 218026826
- EPA product ID
- 4570337
- Compressor staging
- Variable-speed
- Refrigerant
- R-454B
- Cooling capacity
- 35,000 Btu/h
- SEER2
- 18
- EER2
- 10
- HSPF2
- 9.5
- Heat at 47°F
- 35,000 Btu/h
- Heat at 17°F
- 30,800 Btu/h
- Heat at 5°F
- 32,800 Btu/h
- COP at 5°F
- 2
What the numbers mean
For each million Btu of seasonal cooling, the published SEER2 works out to 55.6 kWh.
At the published 5°F test point, the system delivers 32,800 Btu/h. Compare that with the heating load at the same temperature.
At 5°F the unit delivers 94% of its listed 47°F heating output (32,800 versus 35,000 Btu/h).
The rating includes furnace YP9C100C16MP13. Ask for the rating of the new combination if the proposal keeps another furnace.
Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.
Source record
Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.