HVAC MatchupQuote worksheet

Rated equipment configuration

Carrier 27SCA524A**30* · rating 214133215

The published rating for this configuration lists 24,000 Btu/h of cooling. Check the indoor model CAA**3721AM* against your proposal.

Equipment on the rating

System type
Split heat pump
Outdoor / packaged model
27SCA524A**30*
Indoor model
CAA**3721AM*
Furnace in this rating
59SU5B040M17**12
AHRI reference
214133215
EPA product ID
3400155
Compressor staging
Single-stage
Refrigerant
R-454B
Cooling capacity
24,000 Btu/h
SEER2
15.2
EER2
11.7
HSPF2
7.8
Heat at 47°F
22,000 Btu/h
Heat at 17°F
15,200 Btu/h
Heat at 5°F
11,800 Btu/h
COP at 5°F
2.1

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 65.8 kWh.

At the published 5°F test point, the system delivers 11,800 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 54% of its listed 47°F heating output (11,800 versus 22,000 Btu/h).

The rating includes furnace 59SU5B040M17**12. Ask for the rating of the new combination if the proposal keeps another furnace.

Seasonal cooling electricity65.8kWh per million Btu0/100Score 0 / 100
Peak cooling power1.03kW per ton at the EER2 test point63/100Score 63 / 100
Seasonal heating electricity128.2kWh per million Btu0/100Score 0 / 100
Heating electricity at 5°F139.6kWh per million Btu at 5°F46/100Score 46 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.