HVAC MatchupQuote worksheet

Rated equipment configuration

American Standard 5A6H6042A1 · rating 218108767

The published rating for this configuration lists 40,000 Btu/h of cooling. Check the indoor model 5TXCD010AS3+TSTAT against your proposal.

Equipment on the rating

System type
Split heat pump
Outdoor / packaged model
5A6H6042A1
Indoor model
5TXCD010AS3+TSTAT
Furnace in this rating
S9X2D120U5PSB
AHRI reference
218108767
EPA product ID
4574151
Compressor staging
Single-stage
Refrigerant
R-454B
Cooling capacity
40,000 Btu/h
SEER2
16
EER2
12
HSPF2
8.1
Heat at 47°F
39,000 Btu/h
Heat at 17°F
25,600 Btu/h
Heat at 5°F
19,200 Btu/h
COP at 5°F
2.22

What the numbers mean

For each million Btu of seasonal cooling, the published SEER2 works out to 62.5 kWh.

At the published 5°F test point, the system delivers 19,200 Btu/h. Compare that with the heating load at the same temperature.

At 5°F the unit delivers 49% of its listed 47°F heating output (19,200 versus 39,000 Btu/h).

The rating includes furnace S9X2D120U5PSB. Ask for the rating of the new combination if the proposal keeps another furnace.

Seasonal cooling electricity62.5kWh per million Btu18/100Score 18 / 100
Peak cooling power1.00kW per ton at the EER2 test point72/100Score 72 / 100
Seasonal heating electricity123.5kWh per million Btu17/100Score 17 / 100
Heating electricity at 5°F132.0kWh per million Btu at 5°F69/100Score 69 / 100

Scores compare published readings within this equipment type in our catalog. Lower electricity use earns a higher score. See the formulas.

Source record

Check the source record for model wildcards. A listed furnace is part of the rated combination whenever the source names one.